Detail SP-AA 4000 SPECTRUM INSTRUMENT GmbH GERMANY






1 unit




SP-AA 4000 SPECTRUM






 




 






 




High light throughput Single Beam and True Double Beam. The SP-AA 4000 is a fully automated computer controlled Flame AAS instrument featuring an 8-lamp turret, automatic gas box and automatic burner height setting. The majority of samples will run smoothly with this instrument, if the stored default methods are applied. In case of unique challenges our application experts will take personal responsibility for responding to the customer”s needs.






 




 






 




Monochromator




Czerny-Turner- type with 2 focal lengths at 355.8 and 345.6 mm, automated wavelength selection and slit selection. The system provides a true double beam mode.






 




Wavelength range




185 – 900 nm






 




Modes of Operation




Atomic Absorption and Atomic Emission






 




Grating




Holographic grating with 1800 lines/mm






 




Detector




Wide range UV sensitive photomultiplier tube






 




Slits




Automated 6 slit selection 0.1; 0.2; 0.5; 0.7; 1.4 and 2.0 nm






 




Lamp




Automated 8-lamp turret with independent lamp power supply to each lamp and with two heating circuits for preheating lamp operation






 




Background Correction




Deuterium (D2) Background Correction and Smith-Hieftje(Self-absorption)Background Correction.






 




 




 






 




Flame System




 






 




Burner-Nebulizer System




All-titanium 100 mm and 50 mm burners are available for air / acetylene gases and for acetylene / nitrous oxide flame. Adjustable nebulizer with internal Platinum / Iridium capillary, PEEK Nozzle and fixed ceramic impact bead are supplied as standard. SP-AA 4000 features automated setting of burner height for each elements.






 




Spray Chamber




The PPS (Polyphenylene Sulfide)  spray chamber is used for both aqueous and organic solution






 




Gas Controls




Software controlled gas box allows the automatic setting of gas flows for each element.Acetylene flow is automatically adjusted prior to the oxidant change when switching to or from nitrous oxide-acetylene operation.






 




Safety Function




Interlocked safety system prevents selection of the nitrous oxide flame if the nitrous oxide burner is not fitted. Sensor controls for protection to use the incorrect burner head and check the siphon system. In case of pressure failure of fuel or oxidant gas, or power failure, safety interlocks will shut down the gases automatically in the right order.







1 Set




Hydride System






-




The Hydride system is a continious flow  technique  for Determine Hg, As, Se, Sb, Te, Sn, Bi






-




Range concentration analyse at ppb






-




The Hg will be Determin ed with the cold Vapour technique






-




The System has the gas flow control including two peristaltic pump for supplay the reagen, acid, and sample






 




 






1x




Burner Head Acetylene/Nitrous Oxide, 50mm






1x




Burner Head Acetylene/Air Flame,100mm






8x




Hollow Cathode Lamps : Na,K,Mg,Ca,Pb,Hg,Cd,As






8x




Standar Solution : Na,K,Mg,Ca,Pb,Hg,Cd,As






1x




Regulator Acetylene






1x




Regulator N2O






1x




Regulator Argon






1x




Gas Acetylene + Cylinder






1x




Gas N2O + Cylinder






1x




Gas Argon + Cylinder






1x




Blower, Vent, & Flexible Ducting






1 unit




Oiless Compressor






1 unit




Software SPWIN-AAS






1 Set




Control & Evaluation unit,  Intel (R) Corei5 (TM) RAM 4 GB 500 GB, USB, Optical Mouse, USB Keyboard, DVDRW integrated video, LED, monitor 18.5”






1 unit




Printer Laser Jet









Tampilkan Lebih Banyak

pt. sumber arum abadi
pt. sumber arum abadi

PT. Sumber Arum Abadi

Anggota PREMIUM 10 Tahun
Ruko Graha Indah Blok B No.4 Kec.Gayungan Jl. Gayung Kebonsari, Surabaya
Indonesia 60235
Surabaya
11 / 07 / 2018

Detail SP-AA 4000 SPECTRUM INSTRUMENT GmbH GERMANY






1 unit




SP-AA 4000 SPECTRUM






 




 






 




High light throughput Single Beam and True Double Beam. The SP-AA 4000 is a fully automated computer controlled Flame AAS instrument featuring an 8-lamp turret, automatic gas box and automatic burner height setting. The majority of samples will run smoothly with this instrument, if the stored default methods are applied. In case of unique challenges our application experts will take personal responsibility for responding to the customer”s needs.






 




 






 




Monochromator




Czerny-Turner- type with 2 focal lengths at 355.8 and 345.6 mm, automated wavelength selection and slit selection. The system provides a true double beam mode.






 




Wavelength range




185 – 900 nm






 




Modes of Operation




Atomic Absorption and Atomic Emission






 




Grating




Holographic grating with 1800 lines/mm






 




Detector




Wide range UV sensitive photomultiplier tube






 




Slits




Automated 6 slit selection 0.1; 0.2; 0.5; 0.7; 1.4 and 2.0 nm






 




Lamp




Automated 8-lamp turret with independent lamp power supply to each lamp and with two heating circuits for preheating lamp operation






 




Background Correction




Deuterium (D2) Background Correction and Smith-Hieftje(Self-absorption)Background Correction.






 




 




 






 




Flame System




 






 




Burner-Nebulizer System




All-titanium 100 mm and 50 mm burners are available for air / acetylene gases and for acetylene / nitrous oxide flame. Adjustable nebulizer with internal Platinum / Iridium capillary, PEEK Nozzle and fixed ceramic impact bead are supplied as standard. SP-AA 4000 features automated setting of burner height for each elements.






 




Spray Chamber




The PPS (Polyphenylene Sulfide)  spray chamber is used for both aqueous and organic solution






 




Gas Controls




Software controlled gas box allows the automatic setting of gas flows for each element.Acetylene flow is automatically adjusted prior to the oxidant change when switching to or from nitrous oxide-acetylene operation.






 




Safety Function




Interlocked safety system prevents selection of the nitrous oxide flame if the nitrous oxide burner is not fitted. Sensor controls for protection to use the incorrect burner head and check the siphon system. In case of pressure failure of fuel or oxidant gas, or power failure, safety interlocks will shut down the gases automatically in the right order.







1 Set




Hydride System






-




The Hydride system is a continious flow  technique  for Determine Hg, As, Se, Sb, Te, Sn, Bi






-




Range concentration analyse at ppb






-




The Hg will be Determin ed with the cold Vapour technique






-




The System has the gas flow control including two peristaltic pump for supplay the reagen, acid, and sample






 




 






1x




Burner Head Acetylene/Nitrous Oxide, 50mm






1x




Burner Head Acetylene/Air Flame,100mm






8x




Hollow Cathode Lamps : Na,K,Mg,Ca,Pb,Hg,Cd,As






8x




Standar Solution : Na,K,Mg,Ca,Pb,Hg,Cd,As






1x




Regulator Acetylene






1x




Regulator N2O






1x




Regulator Argon






1x




Gas Acetylene + Cylinder






1x




Gas N2O + Cylinder






1x




Gas Argon + Cylinder






1x




Blower, Vent, & Flexible Ducting






1 unit




Oiless Compressor






1 unit




Software SPWIN-AAS






1 Set




Control & Evaluation unit,  Intel (R) Corei5 (TM) RAM 4 GB 500 GB, USB, Optical Mouse, USB Keyboard, DVDRW integrated video, LED, monitor 18.5”






1 unit




Printer Laser Jet