Hi, Guest!

Schneider MiCom P127

Update Terakhir
:
17 / 04 / 2019
Min. Pembelian
:
1 Unit
Harga Mulai
Rp. 19.888.000
Sampai dengan
Rp. 19.999.000
Bagikan
:

Detail Schneider MiCom P127

Schneider MiCom P127

MiCOM P127 - Overcurrent and earth fault protection relay-30 TE-Standard display

range of product = MiCOM P127
device short name = P127
relay application = Feeder

protection type :    
Cold load pick-up
Breaker failure 50BF
Lockout 86
Phase undercurrent 37
Recloser 79
Overcurrent 50/51
Earth fault 50G/51G
Negative sequence overvoltage 47
Undervoltage 27
Overvoltage 59
Rate of change of frequency 81R
Neutral voltage displacement 59N
Underfrequency 81L
Negative sequence overcurrent 46
Directional earth fault 67N
Overfrequency 81O
Directional phase overcurrent 67
Restricted earth fault 64REF
Voltage-restrained overcurrent 50V/51V
Thermal overload protection 49RMS

number of inputs :
4 current input CT...X/5 A and X/1 A
3 voltage
12 discrete

number of outputs = 9 discrete

communication port protocol :
DNP3
IEC 60870-5-103
Modbus RTU

Complementary :
[Us] rated supply voltage    
24...250 V DC 19.2...300 V
48...250 V DC 38.4...300 V
48...240 V AC 38.4...264 V

control and monitoring type = Circuit breaker/contactor control

network and machine diagnosis type :    
Fault recording
Event recording
Disturbance recording (15 s

switchgear diagnosis type :
CT/VT supervision
Trip circuit supervision TCS

display type :
Backlit LCD 2 lines of 16 characters
discrete input voltage    
24...250 V DC (Threshold : 19.2 V (Threshold : standard variant)
48...250 V AC (Threshold : 19.2 V (Threshold : standard variant)
48...250 V DC (Threshold : 105 V (Threshold : further option)
48...250 V DC (Threshold : 77 V (Threshold : further option)
48...250 V DC (Threshold : 154 V (Threshold : further option)
48...240 V AC (Threshold : 105 V (Threshold : further option)
48...240 V AC (Threshold : 77 V (Threshold : further option)
48...240 V AC (Threshold : 154 V (Threshold : further option)

communication port support :
RS232
RS485

Environment
type of measurement = Current
height :
177 mm total
156 mm embedded
width = 155 mm
depth :    
249.6 mm total
223 mm embedded
device mounting = Flush
safety relay

Tampilkan Lebih Banyak

Sumber Berkat Abadi

SUMBER BERKAT ABADI
Kami Specialist menyediakan :
 
1. Auto Synchronous Generator
= Woodward, Smartgen, ComAp, Datakom
Speed Control & Actuator
= Woodward, GAC, Segma, Cummins
 
2. Battery Charger
= BAE, SEG, Smartgen BAC, CSS, Aspire, Datakom SMPS & Firetrol
 
3. AVR
= Stamford, Leroy Somer, Marrelli, Mecc Alte, Taiyo, Basler, Caterpillar, OEM
 
4. VDO Gauge & VDO Sender
 
5. Turbocharger
= Holset, Garrett, KMP, Perkins, IHI, Mitsubishi, Caterpillar
 
6. Relay Protection, Overcurrent, Overvoltage & Trafo
= Broyce Control & SEG
 
7. Solenoid & MPU
= Woodward, HEL, Deutz, Kubota, DENSO, OEM
 
8. Stater Motor & Alternator
= Bosch, Mahle, Iskra, Delco Remy, Hitachi, OEM
COS
= Smartgen & Kyoritsu
 
9. Fuse MV
= SIBA, Bussmann, Schneider, Siemens
 
10. Spare Parts Generator
= Cummins, Komatsu, Perkins, Deutz, Caterpillar, Yanmar & Kubota
 
11. Undercarriage Excavator
 
12. Potensiometer, Dioda, Switch, Connector
= Vishay Spectrol, Bourns
 
HP / WA : 08788-24-000-19
Bpk. Sonny Pranata
sumber berkat abadi
sumber berkat abadi

Sumber Berkat Abadi

PREMIUM GOLD 5 Tahun
Jl. Pintu Air 3 No. 25-C Pasar Baru, Jakarta Pusat
Indonesia 10710
Jakarta Pusat
26 / 06 / 2019
Hubungi Kami

Detail Schneider MiCom P127

Schneider MiCom P127

MiCOM P127 - Overcurrent and earth fault protection relay-30 TE-Standard display

range of product = MiCOM P127
device short name = P127
relay application = Feeder

protection type :    
Cold load pick-up
Breaker failure 50BF
Lockout 86
Phase undercurrent 37
Recloser 79
Overcurrent 50/51
Earth fault 50G/51G
Negative sequence overvoltage 47
Undervoltage 27
Overvoltage 59
Rate of change of frequency 81R
Neutral voltage displacement 59N
Underfrequency 81L
Negative sequence overcurrent 46
Directional earth fault 67N
Overfrequency 81O
Directional phase overcurrent 67
Restricted earth fault 64REF
Voltage-restrained overcurrent 50V/51V
Thermal overload protection 49RMS

number of inputs :
4 current input CT...X/5 A and X/1 A
3 voltage
12 discrete

number of outputs = 9 discrete

communication port protocol :
DNP3
IEC 60870-5-103
Modbus RTU

Complementary :
[Us] rated supply voltage    
24...250 V DC 19.2...300 V
48...250 V DC 38.4...300 V
48...240 V AC 38.4...264 V

control and monitoring type = Circuit breaker/contactor control

network and machine diagnosis type :    
Fault recording
Event recording
Disturbance recording (15 s

switchgear diagnosis type :
CT/VT supervision
Trip circuit supervision TCS

display type :
Backlit LCD 2 lines of 16 characters
discrete input voltage    
24...250 V DC (Threshold : 19.2 V (Threshold : standard variant)
48...250 V AC (Threshold : 19.2 V (Threshold : standard variant)
48...250 V DC (Threshold : 105 V (Threshold : further option)
48...250 V DC (Threshold : 77 V (Threshold : further option)
48...250 V DC (Threshold : 154 V (Threshold : further option)
48...240 V AC (Threshold : 105 V (Threshold : further option)
48...240 V AC (Threshold : 77 V (Threshold : further option)
48...240 V AC (Threshold : 154 V (Threshold : further option)

communication port support :
RS232
RS485

Environment
type of measurement = Current
height :
177 mm total
156 mm embedded
width = 155 mm
depth :    
249.6 mm total
223 mm embedded
device mounting = Flush
safety relay

Tampilkan Lebih Banyak

Sumber Berkat Abadi

SUMBER BERKAT ABADI
Kami Specialist menyediakan :
 
1. Auto Synchronous Generator
= Woodward, Smartgen, ComAp, Datakom
Speed Control & Actuator
= Woodward, GAC, Segma, Cummins
 
2. Battery Charger
= BAE, SEG, Smartgen BAC, CSS, Aspire, Datakom SMPS & Firetrol
 
3. AVR
= Stamford, Leroy Somer, Marrelli, Mecc Alte, Taiyo, Basler, Caterpillar, OEM
 
4. VDO Gauge & VDO Sender
 
5. Turbocharger
= Holset, Garrett, KMP, Perkins, IHI, Mitsubishi, Caterpillar
 
6. Relay Protection, Overcurrent, Overvoltage & Trafo
= Broyce Control & SEG
 
7. Solenoid & MPU
= Woodward, HEL, Deutz, Kubota, DENSO, OEM
 
8. Stater Motor & Alternator
= Bosch, Mahle, Iskra, Delco Remy, Hitachi, OEM
COS
= Smartgen & Kyoritsu
 
9. Fuse MV
= SIBA, Bussmann, Schneider, Siemens
 
10. Spare Parts Generator
= Cummins, Komatsu, Perkins, Deutz, Caterpillar, Yanmar & Kubota
 
11. Undercarriage Excavator
 
12. Potensiometer, Dioda, Switch, Connector
= Vishay Spectrol, Bourns
 
HP / WA : 08788-24-000-19
Bpk. Sonny Pranata