Jual ROR Heat Detector Adressable / Fixed Heat Detector Adressable ( 4098-9733 ) Jawa Timur - CV. Cipta Nusantara | Indonetwork
Produk atau jasa ini sudah tidak dijual, silakan hubungi perusahaan bersangkutan untuk keterangan lebih lanjut.

ROR Heat Detector Adressable / Fixed Heat Detector Adressable ( 4098-9733 )

Update Terakhir
01 / 12 / 2019
Minimum Pembelian
1 Unit
Dilihat Sebanyak
51 Kali

Harga
CALL  

Bagikan

+ Keranjang

Perhatian!

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Spesifikasi ROR Heat Detector Adressable / Fixed Heat Detector Adressable ( 4098-9733 )

Cari berbagai macam dari pilihan terlengkap Baju Muslim Wanita. Cari penawaran terbaik dan termurah dari supplier terlengkap di Indonetwork.
TrueAlarm® analog sensing provides: • Digital transmission of analog sensor values via IDNet™ or MAPNET II ® two-wire communications* * For use with the following Simplex® products: • 4010 and 4100U Series control panels; and 4008 Series control panels with reduced feature set ( refer to data sheet S4008-0001 for details) • 4020, 4100, and 4120 Series control panels, Universal Transponders and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides: • Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection • Sensitivity monitoring satisfying NFPA 72® sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity • Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot • Ability to display and print detailed sensor information in plain English language Heat sensors provide: • Fixed temperature sensing • Rate-of-rise temperature sensing • Utility temperature sensing 4098-9733 Heat Sensor TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F ( 8.3° C) or 20° F ( 11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F ( 57.2° C) or 155° F ( 68° C) . In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F ( 0° C to 68° C) . This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. General features: • UL listed to Standard 268 • Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted • Designed for EMI compatibility • Magnetic test feature is provided • Optional accessories include remote LED alarm indicator and output relays Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor’ s present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor’ s average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors ( dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/ Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection ( such as more sensitive at night, less sensitive during day) . Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base’ s LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base’ s LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors.
Tampilkan Lebih Banyak

CV. Cipta Nusantara

CV. CIPTA NUSANTARA

CV. Cipta Nusantara merupakan perusahaan yang bergerak di bidang Sistem Perlindungan Kebakaran yang dapat membantu memberikan solusi perlindungan atas aset berharga dari bahaya kebakaran.
Cipta Nusantara sanggup bersaing dalam pelayanan baik berstandar internasional maupun nasional dengan motto "Kami Siap Memberikan Yang Terbaik".
Kami menjual semua peralatan dan sistem pemadam kebakaran dengan kualitas terbaik dan harga kompetitif.

Produk yang kami tawarkan antara lain :
1. Fire Alarm System (Alarm Kebakaran) dengan merk SIMPLEX & NOTIFIER (Conventional, Addressable, Releasing, Networking and Integrated Systems).
2. Fire Suppression System dengan gas clean agent FM-200, Novec TM 1230, IG55 & IG541 (Pemadaman Api / Kebakaran Secara Otomatis menggunakan gas FM 200, gas Novec TM 1230, IG55 & IG541) dengan merk KIDDE & LPG TYCO.
3. Desain, Pengadaan, Instalasi, Test Commissioning & Maintenance.

Saat ini kami berfokus pada efisiensi proses, pemilihan produk yang tepat, dan pengerjaan oleh tim ahli mulai dari desain Desain , Pengadaan, Instalasi, Test Commissioning & Maintenance.

Cipta Nusantara membantu anda memiliki perlindungan terhadap bahaya kebakaran. Bahkan memberi keamanan, keselamatan, dan melindungi aset penting industrial anda.

Untuk Detail Produk anda dapat melihat pada "Katalog Produk" kami.
Anda juga bisa kunjungi website pribadi kami http://www.cnfire.co.id .
 
Tampilkan Lebih Banyak

CV. Cipta Nusantara

Free
Sinar Mas Land Plaza, 12A Floor, Jl. Pemuda No. 60-70 Surabaya - Kota Surabaya, Jawa Timur, Indonesia -60271
Login Terakhir 14 / 07 / 2022