Back to Top

Hi, Guest!

Notifier Fire Alarm Panel, Type: NFS2 640

Update Terakhir
:
08 / 12 / 2019
Min. Pembelian
:
0 Unit
Dilihat Sebanyak
:
91 kali
Harga
CALL
Bagikan
:

Detail Notifier Fire Alarm Panel, Type: NFS2 640

NFS2-640( E) Intelligent Addressable Fire Alarm System Contact: www.metrotama.com General The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products 2 meet virtually every application requirement. Designed with modularity and for ease of system planning, the NFS2-640 can be configured with just a few devices for small building applications, or for a large campus or high-rise application. Simply add additional peripheral equipment to suit the application. NOTE: Unless called out with a version-specific “ E” at the end of the part number, “ NFS2-640” refers to models NFS2-640 and NFS2-640E; similarly, “ CPU2-640” refers to models CPU2-640 and CPU2-640E. Features • Listed to UL Standard 864, 9th edition. • One, expandable to two, isolated intelligent Signaling Line Circuit ( SLC) Style 4, 6 or 7. • Up to 159 detectors ( any mix of ion, photo, thermal, or multisensor) and 159 modules ( Addressable pull stations, normally open contact devices, two-wire smoke, notification, or relay) per SLC. 318 devices per loop/ 636 per FACP or network node. • Standard 80-character display, 640-character large display, or display-less ( a node on a network) . • Network options: – High-speed network for up to 200 nodes ( NFS2-3030, NFS2-640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, and NCA) . – Standard network for up to 103 nodes ( NFS2-3030, NFS2-640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/ 400, AFP-1010, and AM2020) . Up to 54 nodes when DVC is used in network paging. • 6.0 amp switch mode power supply with four Class A/ B builtin Notification Appliance Circuits ( NAC) . Selectable System Sensor, Wheelock, or Gentex strobe synchronization. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. • Autoprogramming and Walk Test reports. • Optional universal 636-point DACT. • 80-character remote annunciators ( up to 32) . • EIA-485 annunciators, including custom graphics. • Printer interface ( 80-column and 40-column printers) . • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. • Alarm Verification selection per point, with tally. • Autoprogramming and Walk Test reports. • Presignal/ Positive Alarm Sequence ( PAS) . • Silence inhibit and Auto Silence timer options. • March time/ temporal/ California two-stage coding/ strobe synchronization. • Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate. • Full QWERTY keypad. • Battery charger supports 18 – 200 amp hour batteries. • Non-alarm points for lower priority functions. • Remote ACK/ Signal Silence/ System Reset/ Drill via monitor modules. • Automatic time control functions, with holiday exceptions. • Surface Mount Technology ( SMT) electronics. • Extensive, built-in transient protection. • Powerful Boolean logic equations. NCA-2 640-CHARACTER DISPLAY FEATURES: • Backlit, 640-character display. • Supports SCS Series smoke control system in both HVAC or FSCS modes ( not UL-Listed for FSCS) . • Printer and CRT EIA-232 ports. • EIA-485 annunciator and terminal mode ports. • Alarm, Trouble, Supervisory, and Security relays. FLASHSCAN® INTELLIGENT FEATURES: • Poll up to 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high-precision protocol ( U.S. Patent 5, 539, 389) . • Manual sensitivity adjustment — nine levels. • Pre-alarm ONYX intelligent sensing — nine levels. • Day/ Night automatic sensitivity adjustment. • Sensitivity windows: – Ion – 0.5 to 2.5% / foot obscuration. – Photo – 0.5 to 2.35% / foot obscuration. – Laser ( VIEW® ) – 0.02 to 2.0% / foot obscuration. – Acclimate Plus™ – 0.5 to 4.0% / foot obscuration. – IntelliQuad™ – 1.0 to 4.0% / foot obscuration. • Drift compensation ( U.S. Patent 5, 764, 142) . • Degraded mode — in the unlikely event that the CPU2-640 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU2-640 NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/ Enable switch for this feature. Page 2 of 8 — dn-7111: c • 05/ 12/ 2009 • Multi-detector algorithm involves nearby detectors in alarm decision ( U.S. Patent 5, 627, 515) . • Automatic detector sensitivity testing ( NFPA-72 compliant) . • Maintenance alert ( two levels) . • Self-optimizing pre-alarm. FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR • Detects all four major elements of a fire ( smoke, heat, CO, and flame) . • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. • Six sensitivity levels. FSL-751 ( VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY: • Revolutionary spot laser design. • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals ( U.S. Patent 5, 831, 524) . • Addressable operation pinpoints the fire location. • No moving parts to fail or filters to change. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE PLUS LOW-PROFILE INTELLIGENT MULTI-SENSOR: • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based technology; combination photo and thermal technology. • FlashScan or classic mode compatible. • Low-temperature warning signal at 40° F ± 5° F ( 4.44° C ± 2.77° C) . RELEASING FEATURES: • Ten independent hazards. • Sophisticated cross-zone ( three options) . • Delay timer and Discharge timers ( adjustable) . • Abort ( four options) . • Low-pressure CO2 listed. VOICE AND TELEPHONE FEATURES: • Up to eight channels of digital audio. • 50 and 75 watt digital amplifiers ( DAA series) . • Solid-state digital message generation. • Firefighter telephone option. • 30- to 120-watt high-efficiency amplifiers ( AA Series) . • Backup tone generator and amplifier option. • Multichannel voice transponder ( XPIQ) . HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 AMP POWER SUPPLY ( 6.0 A IN ALARM) : • 120 VAC ( NFS2-640) ; 240 VAC ( NFS2-640E) . • Displays battery current/ voltage on panel ( with display) .

Tampilkan Lebih Banyak

METROTAMA MODERN

Selamat Datang CV. Metrotama Modern

Kami merupakan perusahaan yang berdiri sejak 2008 bergerak dalam industry FIRE ALARM SYSTEM.

Menyediakan Fire Alarm, System Pemadam Kebakaran, Fire Suppression, Keselamatan kerja, Sistem keamanan termasuk di dalamnya adalah Access Control System, Alarm kebakaran, alarm keamanan, CCTV, Kontrol pintu gerbang otomatis, Sistem pemadaman api otomatis dengan menggunakan media gas yang ramah lingkungan, dll. Fire Protection System : Fire Alarm (Tyco, Thorn, Notifier, Simplex, Hochiki, GST, Appron, Hooseki, Nohmi, dll) Fire Hydrant ( Appron, Hoosek, Zeki, Protec dll) Fire Sprinkler ( Viking, Tyco, Protector dll) Fire Extinquisher ( Gunnebo, Chubb, Servvo, Appron, Hooseki, Viking dll) Fire Suppression ( Fike, Simplex, Kidde, Firewall dll) Fire Pump ( Ebara, Tohatsu, Shibaura, FireTruck, Fire Jeep dll ) Fireman Suits/ Fire Fighter ( Nomex IIIA Dupont, MSA dll) Security System : a. CCTV ( Panasonic, Sony, Samsung, Bosch, Calion dll) b. Burglar ( Ademco, Honeywell, Omnicron, Paradox, DSC dll) c. Access Control ( Rosslare, Guardall, Falco, dll ) IT, Network & Telecomunication a. IT & Network : CISCO, Alied Telesis, IBM, HP, SMC, dll b. Telecomunication : PABX Panasonic, IP PABX, FAX dll Dijamin kualitas baik, baru dan harga murah. Fire Alarm Surabaya, Fire Protection Surabaya

metrotama modern
metrotama modern

METROTAMA MODERN

PREMIUM GOLD 5 Tahun
Griya Kebraon Selatan V/E-20, Karangpilang Surabaya
Jawa Timur , Indonesia, SURABAYA
Indonesia 60222
SURABAYA
07 / 12 / 2019
Hubungi Kami
BEST DEAL

Detail Notifier Fire Alarm Panel, Type: NFS2 640

NFS2-640( E) Intelligent Addressable Fire Alarm System Contact: www.metrotama.com General The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products 2 meet virtually every application requirement. Designed with modularity and for ease of system planning, the NFS2-640 can be configured with just a few devices for small building applications, or for a large campus or high-rise application. Simply add additional peripheral equipment to suit the application. NOTE: Unless called out with a version-specific “ E” at the end of the part number, “ NFS2-640” refers to models NFS2-640 and NFS2-640E; similarly, “ CPU2-640” refers to models CPU2-640 and CPU2-640E. Features • Listed to UL Standard 864, 9th edition. • One, expandable to two, isolated intelligent Signaling Line Circuit ( SLC) Style 4, 6 or 7. • Up to 159 detectors ( any mix of ion, photo, thermal, or multisensor) and 159 modules ( Addressable pull stations, normally open contact devices, two-wire smoke, notification, or relay) per SLC. 318 devices per loop/ 636 per FACP or network node. • Standard 80-character display, 640-character large display, or display-less ( a node on a network) . • Network options: – High-speed network for up to 200 nodes ( NFS2-3030, NFS2-640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, and NCA) . – Standard network for up to 103 nodes ( NFS2-3030, NFS2-640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/ 400, AFP-1010, and AM2020) . Up to 54 nodes when DVC is used in network paging. • 6.0 amp switch mode power supply with four Class A/ B builtin Notification Appliance Circuits ( NAC) . Selectable System Sensor, Wheelock, or Gentex strobe synchronization. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. • Autoprogramming and Walk Test reports. • Optional universal 636-point DACT. • 80-character remote annunciators ( up to 32) . • EIA-485 annunciators, including custom graphics. • Printer interface ( 80-column and 40-column printers) . • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. • Alarm Verification selection per point, with tally. • Autoprogramming and Walk Test reports. • Presignal/ Positive Alarm Sequence ( PAS) . • Silence inhibit and Auto Silence timer options. • March time/ temporal/ California two-stage coding/ strobe synchronization. • Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate. • Full QWERTY keypad. • Battery charger supports 18 – 200 amp hour batteries. • Non-alarm points for lower priority functions. • Remote ACK/ Signal Silence/ System Reset/ Drill via monitor modules. • Automatic time control functions, with holiday exceptions. • Surface Mount Technology ( SMT) electronics. • Extensive, built-in transient protection. • Powerful Boolean logic equations. NCA-2 640-CHARACTER DISPLAY FEATURES: • Backlit, 640-character display. • Supports SCS Series smoke control system in both HVAC or FSCS modes ( not UL-Listed for FSCS) . • Printer and CRT EIA-232 ports. • EIA-485 annunciator and terminal mode ports. • Alarm, Trouble, Supervisory, and Security relays. FLASHSCAN® INTELLIGENT FEATURES: • Poll up to 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high-precision protocol ( U.S. Patent 5, 539, 389) . • Manual sensitivity adjustment — nine levels. • Pre-alarm ONYX intelligent sensing — nine levels. • Day/ Night automatic sensitivity adjustment. • Sensitivity windows: – Ion – 0.5 to 2.5% / foot obscuration. – Photo – 0.5 to 2.35% / foot obscuration. – Laser ( VIEW® ) – 0.02 to 2.0% / foot obscuration. – Acclimate Plus™ – 0.5 to 4.0% / foot obscuration. – IntelliQuad™ – 1.0 to 4.0% / foot obscuration. • Drift compensation ( U.S. Patent 5, 764, 142) . • Degraded mode — in the unlikely event that the CPU2-640 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU2-640 NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/ Enable switch for this feature. Page 2 of 8 — dn-7111: c • 05/ 12/ 2009 • Multi-detector algorithm involves nearby detectors in alarm decision ( U.S. Patent 5, 627, 515) . • Automatic detector sensitivity testing ( NFPA-72 compliant) . • Maintenance alert ( two levels) . • Self-optimizing pre-alarm. FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR • Detects all four major elements of a fire ( smoke, heat, CO, and flame) . • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. • Six sensitivity levels. FSL-751 ( VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY: • Revolutionary spot laser design. • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals ( U.S. Patent 5, 831, 524) . • Addressable operation pinpoints the fire location. • No moving parts to fail or filters to change. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE PLUS LOW-PROFILE INTELLIGENT MULTI-SENSOR: • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based technology; combination photo and thermal technology. • FlashScan or classic mode compatible. • Low-temperature warning signal at 40° F ± 5° F ( 4.44° C ± 2.77° C) . RELEASING FEATURES: • Ten independent hazards. • Sophisticated cross-zone ( three options) . • Delay timer and Discharge timers ( adjustable) . • Abort ( four options) . • Low-pressure CO2 listed. VOICE AND TELEPHONE FEATURES: • Up to eight channels of digital audio. • 50 and 75 watt digital amplifiers ( DAA series) . • Solid-state digital message generation. • Firefighter telephone option. • 30- to 120-watt high-efficiency amplifiers ( AA Series) . • Backup tone generator and amplifier option. • Multichannel voice transponder ( XPIQ) . HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 AMP POWER SUPPLY ( 6.0 A IN ALARM) : • 120 VAC ( NFS2-640) ; 240 VAC ( NFS2-640E) . • Displays battery current/ voltage on panel ( with display) .

Tampilkan Lebih Banyak

METROTAMA MODERN

Selamat Datang CV. Metrotama Modern

Kami merupakan perusahaan yang berdiri sejak 2008 bergerak dalam industry FIRE ALARM SYSTEM.

Menyediakan Fire Alarm, System Pemadam Kebakaran, Fire Suppression, Keselamatan kerja, Sistem keamanan termasuk di dalamnya adalah Access Control System, Alarm kebakaran, alarm keamanan, CCTV, Kontrol pintu gerbang otomatis, Sistem pemadaman api otomatis dengan menggunakan media gas yang ramah lingkungan, dll. Fire Protection System : Fire Alarm (Tyco, Thorn, Notifier, Simplex, Hochiki, GST, Appron, Hooseki, Nohmi, dll) Fire Hydrant ( Appron, Hoosek, Zeki, Protec dll) Fire Sprinkler ( Viking, Tyco, Protector dll) Fire Extinquisher ( Gunnebo, Chubb, Servvo, Appron, Hooseki, Viking dll) Fire Suppression ( Fike, Simplex, Kidde, Firewall dll) Fire Pump ( Ebara, Tohatsu, Shibaura, FireTruck, Fire Jeep dll ) Fireman Suits/ Fire Fighter ( Nomex IIIA Dupont, MSA dll) Security System : a. CCTV ( Panasonic, Sony, Samsung, Bosch, Calion dll) b. Burglar ( Ademco, Honeywell, Omnicron, Paradox, DSC dll) c. Access Control ( Rosslare, Guardall, Falco, dll ) IT, Network & Telecomunication a. IT & Network : CISCO, Alied Telesis, IBM, HP, SMC, dll b. Telecomunication : PABX Panasonic, IP PABX, FAX dll Dijamin kualitas baik, baru dan harga murah. Fire Alarm Surabaya, Fire Protection Surabaya