Hi, Guest!

LV429640 MCCB Compact NSX100F TMD 100A 4 Pole

Update Terakhir
:
18 / 04 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:

Detail LV429640 MCCB Compact NSX100F TMD 100A 4 Pole

air circuit breaker product name Compact NSX product or component type Circuit breaker device short name Compact NSX100F device application Distribution poles description 4P protected poles description 3t neutral position Left network type AC network frequency 50/60 Hz [In] rated current 100 A ( 40 °C ) [Ui] rated insulation voltage 800 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 8 kV [Ue] rated operational voltage 690 V AC 50/60 Hz breaking capacity code F (36 kA) AC breaking capacity 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 600 V AC 50/60 Hz conforming to UL 508 25 kA at 480 V AC 50/60 Hz conforming to UL 508 85 kA at 240 V AC 50/60 Hz conforming to UL 508 [Ics] rated service breaking capacity Ics 11 kA 525 V AC 50/60 Hz conforming to IEC 60947-2 Ics 35 kA 440 V AC 50/60 Hz conforming to IEC 60947-2 Ics 36 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2 Ics 4 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2 Ics 85 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2 Ics 12.5 kA 500 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to EN 60947-2 Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit protection functions LI trip unit rating 100 A ( 40 °C ) protection type Overload protection (thermal) L Short-circuit protection (magnetic) I pollution degree 3 conforming to IEC 60664-1
Tampilkan Lebih Banyak

PT. PELANGI CAHAYA SEMPURNA

PT. PELANGI CAHAYA SEMPURNA Adalah Perusahaan yang bergerak dibidang penyedia alat – alat listrik seperti pengadaan barang components panel atau spare parts. Berpegang pengalaman pada bidang electrical serta dengan dukungan para ahli yang selalu memberikan solusi untuk kebutuhan anda

PT. PELANGI CAHAYA SEMPURNA

PREMIUM GOLD 5 Tahun
Jl. Anggrek XII/12 Setiabudi, Jakarta Selatan
Indonesia 12920
Jakarta Selatan
22 / 04 / 2019
Hubungi Kami

Detail LV429640 MCCB Compact NSX100F TMD 100A 4 Pole

air circuit breaker product name Compact NSX product or component type Circuit breaker device short name Compact NSX100F device application Distribution poles description 4P protected poles description 3t neutral position Left network type AC network frequency 50/60 Hz [In] rated current 100 A ( 40 °C ) [Ui] rated insulation voltage 800 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 8 kV [Ue] rated operational voltage 690 V AC 50/60 Hz breaking capacity code F (36 kA) AC breaking capacity 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 600 V AC 50/60 Hz conforming to UL 508 25 kA at 480 V AC 50/60 Hz conforming to UL 508 85 kA at 240 V AC 50/60 Hz conforming to UL 508 [Ics] rated service breaking capacity Ics 11 kA 525 V AC 50/60 Hz conforming to IEC 60947-2 Ics 35 kA 440 V AC 50/60 Hz conforming to IEC 60947-2 Ics 36 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2 Ics 4 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2 Ics 85 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2 Ics 12.5 kA 500 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to EN 60947-2 Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit protection functions LI trip unit rating 100 A ( 40 °C ) protection type Overload protection (thermal) L Short-circuit protection (magnetic) I pollution degree 3 conforming to IEC 60664-1
Tampilkan Lebih Banyak

PT. PELANGI CAHAYA SEMPURNA

PT. PELANGI CAHAYA SEMPURNA Adalah Perusahaan yang bergerak dibidang penyedia alat – alat listrik seperti pengadaan barang components panel atau spare parts. Berpegang pengalaman pada bidang electrical serta dengan dukungan para ahli yang selalu memberikan solusi untuk kebutuhan anda