535 Carbon Dioxide Monitor

Carbon Dioxide Monitor
Easy Assessment of Indoor Air Quality

includes :
2-channel infrared ( IR) sensor measures from 0 to 9999 ppm
± 50 ppm + 2% of measured value up to 5000 ppm
± 100 ppm + 3% of measured value from 5000 to 9999 ppm
Second reference beam allows for compensation of environmental and disturbing influences
No user calibration needed

Narrow CO2 probe allows measuring in fresh air and exhaust air channels

Uses reliable infrared absorption
Physical measuring technique does not display cross-sensitivity to other gases

Long-term sensor stability

Wide measuring range; highly accurate
0 to 9999 ppm ( 0 to 1 Vol. % CO2)

Completely reliable

Records Min, Max, and Mean values

Short-term and long-term monitoring

Simple and economical
Suitable for schools and commercial buildings

9-volt battery operation

Wall mount and printer options

Applications
Testing stationary CO2 transmitters in demand controlled ventilating systems ( DCVs)

Measuring the CO2 concentration in incoming and outgoing ducts

Monitoring indoor air quality in open plan offices

Providing quick readings wherever there is occupant distress
With its high contribution to Sick Building Syndrome ( SBS) , carbon dioxide concentration is frequently used to evaluate indoor air quality and ventilation. The reliable 535 Carbon Dioxide Monitor can be used to quickly and accurately assess carbon dioxide concentration levels on both a short-term and long-term basis. Easy to use and lightweight, the 535 monitor is completely portable. Its simple keypad makes it easy to operate in any setting. No user calibration is needed due to the monitor’ s highly stable sensor. An optional protective case, wall mounting holder, and carrying holder are all available separately.

Carbon Dioxide & IAQ
Elevated CO2 levels can cause occupants to complain of room stuffiness or a stale air smell. This means there is inadequate ventilation. Improper ventilation also promotes the build-up of other chemical and biological contaminants that can cause health effects in occupants. A method for evaluating IAQ is continuous CO2 monitoring using a datalogging instrument. Supplement CO2 monitoring with measurements of temperature, relative humidity, airflow movement, and airflow volume. For more information on products to sample these parameters, see the Indoor Environmental Quality Instruments page.

Performance Profile .
Sensor Two-channel infrared absorption principle
Measuring Range 0 to 9999 ppm CO2 ( 0 to 1 Vol. % CO2)
Accuracy 0 to 5000 ppm: ± 50 ppm + 2% of measured value
5000 to 9999 ppm: ± 100 ppm + 3% of measured value
Resolution 1 ppm or 0.001 Vol. %
Operating Temperature 32 to 122 F
Storage Temperature -4 to 160 F
Battery Life > 6 hr ( 9-V block Al-Mn)
Switchover ppm/ Vol. %
Display LCD, 0.5-in digit height
Housing ABS
Dimensions 7 x 2.25 x 2 in ( 19 x 5.7 x 5.1 cm)
Weight 11 oz ( 312 gm)
Tampilkan Lebih Banyak

alat laboratorium, alat teknik, peralatan instrument lab, peralatan teknik, alat labs ( hp 0815 1311 6206) www.pro-teknik.net | www.alat-labs.com
JL. Taruna Raya No.47D , Pulogadung, Indonesia, Jakarta Timur
Indonesia 13220
Jakarta Timur
20 / 07 / 2018

Detail Jual 535 Carbon Dioxide Monitor, Hub. Bp. Sinaga, Email: Pro.teknik@ Yahoo.co.id; Pro-teknik@ Live.com, Tlpn/ Fax: 021 470 4719, Mobile : 0815 1311 6206 ; 021 93 800 487 ; 08 2124 167 067

535 Carbon Dioxide Monitor

Carbon Dioxide Monitor
Easy Assessment of Indoor Air Quality

includes :
2-channel infrared ( IR) sensor measures from 0 to 9999 ppm
± 50 ppm + 2% of measured value up to 5000 ppm
± 100 ppm + 3% of measured value from 5000 to 9999 ppm
Second reference beam allows for compensation of environmental and disturbing influences
No user calibration needed

Narrow CO2 probe allows measuring in fresh air and exhaust air channels

Uses reliable infrared absorption
Physical measuring technique does not display cross-sensitivity to other gases

Long-term sensor stability

Wide measuring range; highly accurate
0 to 9999 ppm ( 0 to 1 Vol. % CO2)

Completely reliable

Records Min, Max, and Mean values

Short-term and long-term monitoring

Simple and economical
Suitable for schools and commercial buildings

9-volt battery operation

Wall mount and printer options

Applications
Testing stationary CO2 transmitters in demand controlled ventilating systems ( DCVs)

Measuring the CO2 concentration in incoming and outgoing ducts

Monitoring indoor air quality in open plan offices

Providing quick readings wherever there is occupant distress
With its high contribution to Sick Building Syndrome ( SBS) , carbon dioxide concentration is frequently used to evaluate indoor air quality and ventilation. The reliable 535 Carbon Dioxide Monitor can be used to quickly and accurately assess carbon dioxide concentration levels on both a short-term and long-term basis. Easy to use and lightweight, the 535 monitor is completely portable. Its simple keypad makes it easy to operate in any setting. No user calibration is needed due to the monitor’ s highly stable sensor. An optional protective case, wall mounting holder, and carrying holder are all available separately.

Carbon Dioxide & IAQ
Elevated CO2 levels can cause occupants to complain of room stuffiness or a stale air smell. This means there is inadequate ventilation. Improper ventilation also promotes the build-up of other chemical and biological contaminants that can cause health effects in occupants. A method for evaluating IAQ is continuous CO2 monitoring using a datalogging instrument. Supplement CO2 monitoring with measurements of temperature, relative humidity, airflow movement, and airflow volume. For more information on products to sample these parameters, see the Indoor Environmental Quality Instruments page.

Performance Profile .
Sensor Two-channel infrared absorption principle
Measuring Range 0 to 9999 ppm CO2 ( 0 to 1 Vol. % CO2)
Accuracy 0 to 5000 ppm: ± 50 ppm + 2% of measured value
5000 to 9999 ppm: ± 100 ppm + 3% of measured value
Resolution 1 ppm or 0.001 Vol. %
Operating Temperature 32 to 122 F
Storage Temperature -4 to 160 F
Battery Life > 6 hr ( 9-V block Al-Mn)
Switchover ppm/ Vol. %
Display LCD, 0.5-in digit height
Housing ABS
Dimensions 7 x 2.25 x 2 in ( 19 x 5.7 x 5.1 cm)
Weight 11 oz ( 312 gm)