Hi, Guest!

Detection IDMT Relay P9680 Broyce Control

Update Terakhir
:
10 / 12 / 2018
Min. Pembelian
:
1 Unit
Harga Mulai
Rp. 3.788.000
Sampai dengan
Rp. 3.799.000
Bagikan
:

Detail Detection IDMT Relay P9680 Broyce Control

Over current and Earth Fault detection IDMT Relay P9680 Broyce Control

Part Number : P9680

Supply Voltage = 85 - 265 VAC / 85 - 370  VDC


Overcurrent and Earth Fault detection (IDMT)
6 Selectable IDMT curves
Programmable Low-set and High-set tripping
LCD with live display of currents
Last trip memory/history recall
Pre-defined selectable CT ratio’s
Test and Reset buttons
96 x 96mm, Panel Mount
Fully programmable and easy to set-up digital relay that offers the user the ability to monitor and detect Overcurrent and Earth Fault conditions. The user is able to choose from 6 tripping characteristics curves for use on both Overcurrent and Earth fault detection or alternatively, assign a Definite Time. Two relay outputs can be individually assigned to either Overcurrent and/or Earth Fault tripping and set for Manual or Auto-resetting.

SPECIFICATIONS :

Monitoring function: Overcurrent and Earth Fault
Characteristic curves: NI 3/10, NI 1.3/10, Long Time Inverse, Very Inverse, Extremely Inverse, Extremely Inverse 0.65
Overcurrent trip thresholds: 0.5 – 10A (Low-set)/0.5 – 100A (High-set)
Earth trip thresholds: 0.1 – 5A (Low-set)/0.1 – 50A (High-set)
Aux. supply voltage*: 18 – 55VAC/18 – 72VDC or 85 – 265VAC/85 – 370VDC
Output: 2 x SPDT 8A @ 250V (AC1)
Dimensions(mm): W:96 x H:96 x D:100
Product standard(s): IEC 60255-151
Tampilkan Lebih Banyak

Sumber Berkat Abadi

SUMBER BERKAT ABADI
Kami Specialist menyediakan :
 
1. Auto Synchronous Generator
= Woodward, Smartgen, ComAp, Datakom
Speed Control & Actuator
= Woodward, GAC, Segma, Cummins
 
2. Battery Charger
= BAE, SEG, Smartgen BAC, CSS, Aspire, Datakom SMPS & Firetrol
 
3. AVR
= Stamford, Leroy Somer, Marrelli, Mecc Alte, Taiyo, Basler, Caterpillar, OEM
 
4. VDO Gauge & VDO Sender
 
5. Turbocharger
= Holset, Garrett, KMP, Perkins, IHI, Mitsubishi, Caterpillar
 
6. Relay Protection, Overcurrent, Overvoltage & Trafo
= Broyce Control & SEG
 
7. Solenoid & MPU
= Woodward, HEL, Deutz, Kubota, DENSO, OEM
 
8. Stater Motor & Alternator
= Bosch, Mahle, Iskra, Delco Remy, Hitachi, OEM
COS
= Smartgen & Kyoritsu
 
9. Fuse MV
= SIBA, Bussmann, Schneider, Siemens
 
10. Spare Parts Generator
= Cummins, Komatsu, Perkins, Deutz, Caterpillar, Yanmar & Kubota
 
11. Undercarriage Excavator
 
12. Potensiometer, Dioda, Switch, Connector
= Vishay Spectrol, Bourns
 
HP / WA : 08788-24-000-19
Bpk. Sonny Pranata
sumber berkat abadi
sumber berkat abadi

Sumber Berkat Abadi

PREMIUM GOLD 5 Tahun
Jl. Pintu Air 3 No. 25-C Pasar Baru, Jakarta Pusat
Indonesia 10710
Jakarta Pusat
26 / 06 / 2019
Hubungi Kami

Detail Detection IDMT Relay P9680 Broyce Control

Over current and Earth Fault detection IDMT Relay P9680 Broyce Control

Part Number : P9680

Supply Voltage = 85 - 265 VAC / 85 - 370  VDC


Overcurrent and Earth Fault detection (IDMT)
6 Selectable IDMT curves
Programmable Low-set and High-set tripping
LCD with live display of currents
Last trip memory/history recall
Pre-defined selectable CT ratio’s
Test and Reset buttons
96 x 96mm, Panel Mount
Fully programmable and easy to set-up digital relay that offers the user the ability to monitor and detect Overcurrent and Earth Fault conditions. The user is able to choose from 6 tripping characteristics curves for use on both Overcurrent and Earth fault detection or alternatively, assign a Definite Time. Two relay outputs can be individually assigned to either Overcurrent and/or Earth Fault tripping and set for Manual or Auto-resetting.

SPECIFICATIONS :

Monitoring function: Overcurrent and Earth Fault
Characteristic curves: NI 3/10, NI 1.3/10, Long Time Inverse, Very Inverse, Extremely Inverse, Extremely Inverse 0.65
Overcurrent trip thresholds: 0.5 – 10A (Low-set)/0.5 – 100A (High-set)
Earth trip thresholds: 0.1 – 5A (Low-set)/0.1 – 50A (High-set)
Aux. supply voltage*: 18 – 55VAC/18 – 72VDC or 85 – 265VAC/85 – 370VDC
Output: 2 x SPDT 8A @ 250V (AC1)
Dimensions(mm): W:96 x H:96 x D:100
Product standard(s): IEC 60255-151
Tampilkan Lebih Banyak

Sumber Berkat Abadi

SUMBER BERKAT ABADI
Kami Specialist menyediakan :
 
1. Auto Synchronous Generator
= Woodward, Smartgen, ComAp, Datakom
Speed Control & Actuator
= Woodward, GAC, Segma, Cummins
 
2. Battery Charger
= BAE, SEG, Smartgen BAC, CSS, Aspire, Datakom SMPS & Firetrol
 
3. AVR
= Stamford, Leroy Somer, Marrelli, Mecc Alte, Taiyo, Basler, Caterpillar, OEM
 
4. VDO Gauge & VDO Sender
 
5. Turbocharger
= Holset, Garrett, KMP, Perkins, IHI, Mitsubishi, Caterpillar
 
6. Relay Protection, Overcurrent, Overvoltage & Trafo
= Broyce Control & SEG
 
7. Solenoid & MPU
= Woodward, HEL, Deutz, Kubota, DENSO, OEM
 
8. Stater Motor & Alternator
= Bosch, Mahle, Iskra, Delco Remy, Hitachi, OEM
COS
= Smartgen & Kyoritsu
 
9. Fuse MV
= SIBA, Bussmann, Schneider, Siemens
 
10. Spare Parts Generator
= Cummins, Komatsu, Perkins, Deutz, Caterpillar, Yanmar & Kubota
 
11. Undercarriage Excavator
 
12. Potensiometer, Dioda, Switch, Connector
= Vishay Spectrol, Bourns
 
HP / WA : 08788-24-000-19
Bpk. Sonny Pranata