Back to Top

Hi, Guest!

Baking And N2 Reflow Use RF-400

Update Terakhir
:
10 / 05 / 2020
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
13 kali
Harga
CALL
Bagikan
:

Detail Baking And N2 Reflow Use RF-400

 Baking and N2 Reflow Use RF-400

  • New particle filter
    Replaceable without removing the oxygen analyzer from the device
  • Special filter
    Improves oxygen sensor durability and enables devices to be used with a variety of degradation promoting materials.
  • AC wide range power
    Supports AC 100 to 240 V
  • Convenient measurement range
    Measurement range of 0 to 10000 ppm, commonly used in nitrogen reflow systems (0–1% range also selectable)
  • Compact and easy to install
    Shorter depth than conventional devices. Takes up little space.


 

Specification

Measurement principle Battery-powered zirconia oxygen analyzer
Type Desktop type / Panel mount type
Display system 4-digit digital display (concentration display)
Measurement range 0-1 / 10 / 100 / 1000 / 10000ppm(1) / 10 / 100vol% O2; 10-20 to 10-0atm
Automatic range
Repeatability Within ±1% of full scale; 1%≦ Sample gas ≦100% Within ±2%of full scale; 10ppm≦ Sample gas <1% Concentrations under 10ppm are not under the warranty range
Sampling system Continuous suction with internal pump
Sample gas requirements Pressure: Pressurization at 30KPa or less
Flow rate: 1,000-2,000mL/min
Humidity: Dew point below ambient temperature
Temperature: 0-50ºC
Others: Not to contain corrosive gas (fluorine gas, chlorine gas, sulfuric gas, etc.), gas containing organic silicone, flammable ingredients (including gas), oil or moisture
Reference gas Atmospheric air
Recorder output Oxygen level output: 4-20mA; insulated, and load resistance of 550Ω or less
Recorder output range taken as full scale, and oxygen concentration given in linear output
Output range: 0-100% / 0-10% / 10000ppm / 0-100ppm / 0
Automatic/fixed range
Transmission output RS-232C (Optional)
Alarm output FAIL (device error): 1 point
Non-voltage contact; contact capacity: 30VDC/AC or less, 0.5A or less
Contact point closes with device error (contact point operation adjustable)
ALM (concentration alarm): 2 points (H/L)
Non-voltage contact; contact capacity: 30VDC/AC or less, 0.5A or less
Contact point closes with alarm (contact point operation adjustable)
RDY (warmup signal): 1 point
Non-voltage contact; contact capacity: 30VDC/AC or less, 0.5A or less
* Minimum open/close capacity of the non-voltage contact point is 12V or higher; unable to respond to tiny loads
Warmup time Under 5 min.
Dimensions Body: 210(W)×134(H)×300(D)mm (excludes protruding parts)
Weight Approx. 6.5kg
Gas connection INLET: Rc1/4
BYPASS OUT: Rc1/4
OUTLET: Rc1/4
Power 100-240VAC ±5% 200VA 50Hz/60Hz ±2%




Baking and N2 Reflow Use RF-400
Gas Nitrogen
Tampilkan Lebih Banyak

PT. REXINDO OTOTEKNIK

PT. REXINDO OOTEKNIK incorporated in Bekasi, Indonesia to fulfill any rapid development of diverse modern industry commands an ever-increasing need for industrial plants and success of these industries is highly dependent on cooperation with the right partner for the business.

 

PT. REXINDO OOTEKNIK established since 2012 by a group of engineers who have experience in the various fields of engineering that could support any industrial needs especially on Engineering, Technical Services, Instrumentation & Control and Industrial Supplies.

We have some experiences of supplying products in varies kind of industries, such as Oil & Gas, Chemical, Power Generation, Petrochemical, Fertilizer, Coal & Mining, Pharmaceutical, Food Industries, Petrcochemical, etc.

 

Our team of sales engineers possess many years of experience in assisting clients in automated processes to enhance product quality, increase productivity, reduce waste, improve safety, and to meet regulatory requirements. The result is a solution tailored to meet the unique needs of our customers.

 

Therefore we represent some agency from International Company that related with our main business.

pt. rexindo ototeknik
pt. rexindo ototeknik

PT. REXINDO OTOTEKNIK

PREMIUM GOLD 14 Tahun
Sales & Admin Office : Villa Mutiara Bogor Sekttor I Blok C1 No.9
Kelurahan Mekarwangi Kec. Tanah Sareal Kotamadya Bogor Jawa Barat 16168 – INDONESIA
Phone (0251) 7595433 Faximile (0251) 7595433

Office & Workshop : Jl. Toyogiri Selatan No.77 Kel. Jatimulya Kec. Tambun Selatan Bekasi Timur Jawa Barat 17515 – INDONESIA.
Phone: (021) 82746125 Faximile: (021) 82435319, Bekasi
Indonesia 17510
Bekasi
15 / 09 / 2020
Hubungi Kami
BEST DEAL

Detail Baking And N2 Reflow Use RF-400

 Baking and N2 Reflow Use RF-400

  • New particle filter
    Replaceable without removing the oxygen analyzer from the device
  • Special filter
    Improves oxygen sensor durability and enables devices to be used with a variety of degradation promoting materials.
  • AC wide range power
    Supports AC 100 to 240 V
  • Convenient measurement range
    Measurement range of 0 to 10000 ppm, commonly used in nitrogen reflow systems (0–1% range also selectable)
  • Compact and easy to install
    Shorter depth than conventional devices. Takes up little space.


 

Specification

Measurement principle Battery-powered zirconia oxygen analyzer
Type Desktop type / Panel mount type
Display system 4-digit digital display (concentration display)
Measurement range 0-1 / 10 / 100 / 1000 / 10000ppm(1) / 10 / 100vol% O2; 10-20 to 10-0atm
Automatic range
Repeatability Within ±1% of full scale; 1%≦ Sample gas ≦100% Within ±2%of full scale; 10ppm≦ Sample gas <1% Concentrations under 10ppm are not under the warranty range
Sampling system Continuous suction with internal pump
Sample gas requirements Pressure: Pressurization at 30KPa or less
Flow rate: 1,000-2,000mL/min
Humidity: Dew point below ambient temperature
Temperature: 0-50ºC
Others: Not to contain corrosive gas (fluorine gas, chlorine gas, sulfuric gas, etc.), gas containing organic silicone, flammable ingredients (including gas), oil or moisture
Reference gas Atmospheric air
Recorder output Oxygen level output: 4-20mA; insulated, and load resistance of 550Ω or less
Recorder output range taken as full scale, and oxygen concentration given in linear output
Output range: 0-100% / 0-10% / 10000ppm / 0-100ppm / 0
Automatic/fixed range
Transmission output RS-232C (Optional)
Alarm output FAIL (device error): 1 point
Non-voltage contact; contact capacity: 30VDC/AC or less, 0.5A or less
Contact point closes with device error (contact point operation adjustable)
ALM (concentration alarm): 2 points (H/L)
Non-voltage contact; contact capacity: 30VDC/AC or less, 0.5A or less
Contact point closes with alarm (contact point operation adjustable)
RDY (warmup signal): 1 point
Non-voltage contact; contact capacity: 30VDC/AC or less, 0.5A or less
* Minimum open/close capacity of the non-voltage contact point is 12V or higher; unable to respond to tiny loads
Warmup time Under 5 min.
Dimensions Body: 210(W)×134(H)×300(D)mm (excludes protruding parts)
Weight Approx. 6.5kg
Gas connection INLET: Rc1/4
BYPASS OUT: Rc1/4
OUTLET: Rc1/4
Power 100-240VAC ±5% 200VA 50Hz/60Hz ±2%




Baking and N2 Reflow Use RF-400
Gas Nitrogen
Tampilkan Lebih Banyak

PT. REXINDO OTOTEKNIK

PT. REXINDO OOTEKNIK incorporated in Bekasi, Indonesia to fulfill any rapid development of diverse modern industry commands an ever-increasing need for industrial plants and success of these industries is highly dependent on cooperation with the right partner for the business.

 

PT. REXINDO OOTEKNIK established since 2012 by a group of engineers who have experience in the various fields of engineering that could support any industrial needs especially on Engineering, Technical Services, Instrumentation & Control and Industrial Supplies.

We have some experiences of supplying products in varies kind of industries, such as Oil & Gas, Chemical, Power Generation, Petrochemical, Fertilizer, Coal & Mining, Pharmaceutical, Food Industries, Petrcochemical, etc.

 

Our team of sales engineers possess many years of experience in assisting clients in automated processes to enhance product quality, increase productivity, reduce waste, improve safety, and to meet regulatory requirements. The result is a solution tailored to meet the unique needs of our customers.

 

Therefore we represent some agency from International Company that related with our main business.