S9 specifications
Operating pressure range: 4 to 20 cm H2O
Maximum single fault steady state pressure:
30 cm H2O
Pressure measurement tolerance:
± 0.5 cm H2O ± 4% of the measured reading
Flow measurement tolerance: ± 6 L/ min or 10% of
reading, whichever is greater
Dimensions ( L x W x H) : 6.0” x 5.5” x 3.4”
( 153 mm x 140 mm x 86 mm)
Weight: 1.8 lb ( 0.81 kg)
Housing construction: Flame retardant engineering
thermoplastic
Supplemental oxygen: Recommended maximum
supplemental oxygen flow: 4 L/ min
Hypoallergenic air filter: Non-woven acrylic and
polypropylene fibers with polypropylene carrier
Standard air filter: Polyester fiber
Air outlet: 22 mm conical air outlet complies with
ISO 5356-1
General specifications
90W power supply unit:
Input range: 100-240V, 50-60Hz, 110V
400Hz nominal for aircraft use
70W ( 80VA) ( typical power consumption)
110W ( 120VA) ( maximum power consumption)
30W power supply unit:
Input range: 100-240V, 50-60Hz 110V,
400Hz nominal for aircraft use
20W ( 30VA) ( typical power consumption)
36W ( 75VA) ( maximum power consumption)
Operating temperature: 41° F to 95° F
( + 5° C to + 35° C)
Operating humidity: 10-95% non-condensing
Operating altitude: Sea level to 8, 500’ ( 2, 591 m)
Storage and transport temperature:
-4° F to 140° F ( -20° C to + 60° C)
Storage and transport humidity:
10-95% non-condensing
Tampilkan Lebih Banyak

alat laboratorium, www.alat-labs.com, peralatan laboratorium, alat lab ( hp 0815 1311 6206) e-mail: pro-teknik@ hotmail.com, alat uji, alat testing, alat laboratori, peralatan laboratorium, jual alat laboratorium, distributor alat laboratorium
JLN. TARUNA RAYA NO.47D PULOGADUNG, JAKARTA TIMUR
Indonesia 13220
JAKARTA TIMUR
17 / 07 / 2018

Detail Alat Bantu Pernafasan, S9 Specifications Operating Pressure Range: 4 To 20 Cm H2O Maximum Single Fault Steady State Pressure: 30 Cm H2O Pressure Measurement Tolerance: ± 0.5 Cm H2O ± 4% Of The Measured Reading Flow Measurement Tolerance: ± 6 L/ Min Or

S9 specifications
Operating pressure range: 4 to 20 cm H2O
Maximum single fault steady state pressure:
30 cm H2O
Pressure measurement tolerance:
± 0.5 cm H2O ± 4% of the measured reading
Flow measurement tolerance: ± 6 L/ min or 10% of
reading, whichever is greater
Dimensions ( L x W x H) : 6.0” x 5.5” x 3.4”
( 153 mm x 140 mm x 86 mm)
Weight: 1.8 lb ( 0.81 kg)
Housing construction: Flame retardant engineering
thermoplastic
Supplemental oxygen: Recommended maximum
supplemental oxygen flow: 4 L/ min
Hypoallergenic air filter: Non-woven acrylic and
polypropylene fibers with polypropylene carrier
Standard air filter: Polyester fiber
Air outlet: 22 mm conical air outlet complies with
ISO 5356-1
General specifications
90W power supply unit:
Input range: 100-240V, 50-60Hz, 110V
400Hz nominal for aircraft use
70W ( 80VA) ( typical power consumption)
110W ( 120VA) ( maximum power consumption)
30W power supply unit:
Input range: 100-240V, 50-60Hz 110V,
400Hz nominal for aircraft use
20W ( 30VA) ( typical power consumption)
36W ( 75VA) ( maximum power consumption)
Operating temperature: 41° F to 95° F
( + 5° C to + 35° C)
Operating humidity: 10-95% non-condensing
Operating altitude: Sea level to 8, 500’ ( 2, 591 m)
Storage and transport temperature:
-4° F to 140° F ( -20° C to + 60° C)
Storage and transport humidity:
10-95% non-condensing