    Incubator bayi Merk GEA Type YP100 - China,

    Harga:
    Rp. 18.500.000 (Termurah)
    Jumlah Pesanan:
    Tambah ke Keranjang
    Negara Asal:
    China
    Cara Pembayaran:
    Transfer Bank (T/T)
    Kemas & Pengiriman:
    Packing Box
    Spesifikasi :

    Power requirements AC220V-230/ AC110V-120V, 50/ 60Hz
    Power requirements 680VA maximum
    Power outlet AC220V-230V, 50/ 60Hz, Current 2A max
    AC110V-AC120V, 50/ 60Hz, Current 2Amax
    Temperature control range and correlative
    Air mode control 25-37° C
    Temperature rise time ( typical @ 22° C ambient) < 45minutes
    Temperature variability < 0.5° C
    Temperature uniformity ( level mattress) < 0.8° C
    Alarm
    Power alarm power failure
    Motor alarm motor failure
    Motor run speed too low
    Air flow stop
    Sensor alarm Air temperature sensor failure
    Isolate overheating sensor failure
    Air flow sensor failed
    Temperature deviation alarm High/ low air temperature
    Over temperature alarm Air temperature control mode
    Activated if incubator temperature
    not exceeds 38° C
    E² ROM failed internal malfunction
    Environment temperature ( not to use in the environment exceed specified)
    Operating range + 20-+ 30° C
    Storage range -40-+ 70° C
    Environment humidity
    Operating range 30% RH-75% RH non-condensing
    Storage range 10kg
    I.V Pole max. Load 20N
    Hood max. Load 4kg
    Infant mattress max. Load 10kg
    Other specification
    Infant mattress width 31cm
    Infant mattress length 63cm
    Noise level within hood environment < 60dB ( A)
    ( Base on surroundung environment noise below 45dB)
    Carbon diaxide( Co2) level within the hood less than 0.5% when a mixture of Co2 in air is delivered at 750ml/ min at a point 10cm above the center of the mattress.
    Air velocity over mattress less than 0.35m/ s
    Reset Key
    When the following alarm occurs, press RESET/ SILENT key to silence the alarm for 5 minutes, the alarm will come back automatically after 5 minutes. If alarm condition no longer exists, the alarm will be canceled ( except overheat) ; or press the RESET/ SILENT key twice to cancel the alarm, the equipment will come back to set state
    Temperature deviation alarm
    Sensor alarm
    Motor alarm
    Over temperature