Anggota Prioritas Prioritas IndonetworkTahun ke-3
CV ERELHAES REHJAYANA Supplier : Laboratory Equipment, Glassware, Electrical Test, Measuring Instrument, Civil Laboratory Testing Equipment, etc.
Informasi Kontak
Nama:

Tn. Bpk. Juni [Pemasaran]

E-mail:
Nomor Telpon:

Nomor telpon Tn. Bpk. Juni di Jakarta Pusat

Nomor Ponsel:

Nomor ponsel Tn. Bpk. Juni di Jakarta Pusat

Nomor Faks:

Nomor faks Tn. Bpk. Juni di Jakarta Pusat

Alamat:

Jl. Sumur Batu No. 1 RT01-RW06 - Kemayoran
Jakarta Pusat 10640, Jakarta
Indonesia

Alamat Tervalidasi

Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan
Bahasa :

Jual

MEMMERT INCUBATOR IN / IF
Harga Inquary
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Negara AsalJerman
MEMMERT INCUBATORS

Highly sensitive extremely accurate: Incubator I

Overview
Models
Options / Accessories
Inquiry

In the laboratory, our incubator is ideal for all applications with temperatures up to + 80° C – specifically for incubating living cultures at + 37 ° C. Thanks to the finely-tuned control technology, critical temperature overshoots are completely ruled out, valuable loads are therefore warmed up particularly carefully.

Temperature range up to + 80 ° C
8 model sizes 30 to 750
2 model variants: SingleDISPLAY and TwinDISPLAY
Natural convection or forced air circulation N/ F
Double doors ( interior glass, exterior stainless steel) for a clear view without a drop in temperature
Activation of sterilisation routine via ControlCOCKPIT ( TwinDISPLAY)

Memmert incubator - A gentle force in the laboratory

To guarantee optimum air circulation in the incubator chamber even when it is fully loaded, both model variants SingleDISPLAY and TwinDISPLAY are available with an adjustable air fan. Since our unique all-round surface heating is optimally geared to both natural convection and forced air circulation, the fan can be switched off entirely for sensitive samples and for samples which may not be exposed to air turbulence.
Specific use in accordance with the German MPG ( Law on Medical Devices)

In accordance with the German Law on Medical Products ( Directive 93/ 42/ EEC) , the incubators INplus / IFplus can be used for the warming of irrigation solutions and infusions.

Stainless steel – an incubator almost for ever

65 years of permanent development work, as well as numerous amounts of feedback from practical experience, are embodied in each of our incubators:

Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
Heating concept adapted to the specific product for a precise and homogenous temperature control independent of chamber volume and load
A wide range of options for programming and documentation using interfaces, integrated data logger and AtmoCONTROL software
Three-year guarantee for appliances except wear and tear parts
The temperature values of all incubators are measured according to DIN 12880: 2007-05

Incubator IF30 ( Forced air circulation ( Fan) / singleDISPLAY )
Incubator IF30plus ( Forced air circulation ( Fan) / twinDISPLAY )
Incubator IF55plus ( Forced air circulation ( Fan) / twinDISPLAY )
Incubator IF55 ( Forced air circulation ( Fan) / singleDISPLAY )
Incubator IF75 ( Forced air circulation ( Fan) / singleDISPLAY )
Incubator IF75plus ( Forced air circulation ( Fan) / twinDISPLAY )
Incubator IF110 ( Forced air circulation ( Fan) / singleDISPLAY )
Incubator IF110plus ( Forced air circulation ( Fan) / twinDISPLAY )
Incubator IF160 ( Forced air circulation ( Fan) / singleDISPLAY )
Incubator IF160plus ( Forced air circulation ( Fan) / twinDISPLAY )
Incubator IF260 ( Forced air circulation ( Fan) / singleDISPLAY )
Incubator IF260plus ( Forced air circulation ( Fan) / twinDISPLAY )
Incubator IF450 ( Forced air circulation ( Fan) / singleDISPLAY )
Incubator IF450plus ( Forced air circulation ( Fan) / twinDISPLAY )
Incubator IF750plus ( Forced air circulation ( Fan) / twinDISPLAY )
Incubator IF750 ( Forced air circulation ( Fan) / singleDISPLAY )
Incubator IN30 ( Natural air circulation ( Convection) / singleDISPLAY )
Incubator IN30plus ( Natural air circulation ( Convection) / twinDISPLAY )
Incubator IN55 ( Natural air circulation ( Convection) / singleDISPLAY )
Incubator IN55plus ( Natural air circulation ( Convection) / twinDISPLAY )
Incubator IN75plus ( Natural air circulation ( Convection) / twinDISPLAY )
Incubator IN75 ( Natural air circulation ( Convection) / singleDISPLAY )
Incubator IN110 ( Natural air circulation ( Convection) / singleDISPLAY )
Incubator IN110plus ( Natural air circulation ( Convection) / twinDISPLAY )
Incubator IN160plus ( Natural air circulation ( Convection) / twinDISPLAY )
Incubator IN160 ( Natural air circulation ( Convection) / singleDISPLAY )
Incubator IN260 ( Natural air circulation ( Convection) / singleDISPLAY )
Incubator IN260plus ( Natural air circulation ( Convection) / twinDISPLAY )
Incubator IN450 ( Natural air circulation ( Convection) / singleDISPLAY )
Incubator IN450plus ( Natural air circulation ( Convection) / twinDISPLAY )
Incubator IN750plus ( Natural air circulation ( Convection) / twinDISPLAY )
Incubator IN750 ( Natural air circulation ( Convection) / singleDISPLAY )
Membuat situs langsung jadi?Silahkan kunjungi indonetwork.co.id